-40%

Dental Portable Digital X-Ray Imaging System Mobile Film Machine Green Xray Unit

$ 422.39

Availability: 100 in stock
  • Country/Region of Manufacture: China
  • Model: BLX-8Plus
  • Non-Domestic Product: No
  • Brand: Unbranded
  • Modified Item: No
  • Custom Bundle: No
  • Item must be returned within: 30 Days
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Intended Use/Discipline: Dental Laboratory
  • Condition: New
  • MPN: GJ1170100500
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Country of Manufacture: China
  • Bundle Listing: No

    Description

    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays)
    .
    U
    s
    ing a Toshiba
    0.3
    micro-focus tube
    .
    The
    tu
    be voltage
    fre
    quency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS:
    Tube Voltage
    65kv
    Tube Current
    1
    mA
    Time Exposure
    0.1
    ~~
    1.8
    s
    High pressure generator
    30
    kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.
    3
    mm(TOSHIBA)
    Charger Input Voltage
    AC1
    1
    0V~2
    2
    0V
    Supply Frequency
    30
    Hz
    Radiation Leakage
    <2
    0ug
    y/h
    Battery
    24V DC
    2600MA
    Weight
    4.3
    KG
    Dimensions
    37
    cm×
    31
    cm×
    28
    cm (L×W×H)
    Reference of the Angles :
    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure:
    Tooth
    Adult
    Child
    Central & Lateral
    0.
    2
    -
    0.3
    s
    0.2-0.3
    s
    Cuspid & 1
    st
    Bicuspid
    0.3
    -
    0.4
    s
    0.3
    -
    0.4
    s
    Upper 5,6
    0.5
    -
    0.6
    s
    0.5
    -
    0.6
    s
    Upper 7,8
    1.3
    -
    1.8
    s
    1.2
    -
    1.5
    .
    s
    Lower 5,6
    0.5
    -
    0.6
    s
    0.4
    -
    0.5
    s
    Lower
    7,8
    0.6
    -
    0.8
    s
    0.5
    -
    0.7
    s
    Packing List:
    Main machine
    1pcs
    Power line
    1pcs
    User manual
    1pcs
    Operation of the Main Unit :
    Upon re
    ceiv
    ing,open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Turn on the Power

    the pilot lamp will be light up
    .
    During this time,the digital tube  will show the fore se
    ttin
    g time. Now the equipment is in standby mode.
    Sett
    ing the time (Skip to next step if unneeded)
    "+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode

    then press "+" and" -" to set the time needed (time range is
    0.1
    -
    1.8
    seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the t
    oot
    h)
    Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
    After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention

    Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture.
    Keep them steady until the last step of picturing
    ;
    making sure that there is no change in any of their positions.
    Remember to turn the power 0
    ff
    when work is done.
    Cha
    r
    ge the battery if t
    he machine cannot work and the red lamp lignt
    After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady ou
    tp
    ut.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of
    fil
    ming.
    When taking pictures,
    the
    ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use,so as not to damage the delicate component.
    If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other r
    eq
    ues
    ts
    accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo taking, you need to wait for the normal value to return before taking a normal photo

    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:Dentistworld
    City State: SHENZHEN,China
    Telephone number:0755-69985450
    Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding!
    Payment
    We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance.
    Shipping
    The goods you ordered will be posted out in the second working day after the payment has been made. (We will inform you via email if any delay occurred due to holiday events.
    GeneSral shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
    About Us
    If you have any query or dissatisfaction, please find our customer service via eBay Message Center only.
    If you send message via eBay message, we'll reply you within 24 working hours.
    Thank you so much for your purchase. Wish you have a nice day! : -)